
Add to Cart
Constant Temperature Humidity Test Chamber Multifunctional Drug Leakage
Usage :
Constant temperature and humidity chamber is simulation under the condition of product in humid climate
environment combination (high and low temperature operation & storage, temperature cycle,
high temperature and high humidity, low temperature and humidity and condensation test, etc.),
check whether the adaptability and characteristics of the product itself.
Characteristics:
1. Use the high precision microcomputer touch temperature and humidity controller with high stability of
platinum resistance to temperature and wind speed in the circulatory system of temperature and humidity
testing .
2. control temperature&humidity well-distributed, precisely and steady.
3. Completely independent system separate for testing in high temperature, low temperature and constant
temperature&humidity environment.
Technical parameter:
Mode | LY-280 | LY-2150 | LY-2225 | LY-2408 | LY-21000 | |
Inner Size W×H×D(cm) | 40×50×40 | 50×60×50 | 60×85×80 | 60×85×80 | 100×100×100 | |
Outside Size W×H×D(cm) | 93×155×95 | 100×148×106 | 117×166×91 | 140×176×101 | 170×186×111 | |
Volume (V) | 80 L | 150L | 225L | 408L | 800L | |
Temp and Hum Range | A:-20°C~150°C B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C RH20%-98% | |||||
Function | Fluctuation | ±0.5°C ±2.5%RH | ||||
Deviation | ±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH) | |||||
Controller Analytical Accuracy | ±0.3°C ±2.5%RH | |||||
Material | Inner Wall | #SUS 304 Stainless steel | ||||
Outer Skin | #SUS 304 Stainless steel | |||||
Heat Preservation | High temperature resistant, high chlorine acid b vinegar foam insulation materials | |||||
Wind Cycling Way | Centrifugal fan-broadband type forced air circulation | |||||
Refrigeration Way | Single stage compression refrigeration | |||||
Refrigerater | French Tecumseh | |||||
Refrigerants | R4O4A USA Dupont environmental protection refrigerant(R23+R404) | |||||
Condensing Way | Air-cooled or water-cooled | |||||
Heater | Nickel chrome heating wire heater | |||||
Humidifier | Semi-closed steam and wet | |||||
Water Suplying Way | Automatic cycling water supply | |||||
Standard Accessories | 1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 clapboards, 1 bag of wet and dry bulb, 3 fuses, 1 power line. | |||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system |
Picture showing :